All were treated for haematological cancer, 3/7 received haematop

All were treated for haematological cancer, 3/7 received haematopoietic stem cell transplantation (HSCT), and 4/7 received rituximab. Using multivariate analysis, receiving > 1 line of CT was an independent risk factor for HBV-R. Fatal outcome occurred in 3/7 patients (despite lamivudine therapy in two), whereas 2/4 survivors had an HBsAg seroconversion. HBV-R involved non-A HBV genotypes and core promoter and/or precore HBV mutants in all cases. Mutations known to impair HBsAg antigenicity

were detected in HBV DNA from all seven patients. HBV DNA could be retrospectively detected in two patients prior cancer treatment and despite HBsAg negativity. HBV-R is a concern in HBsAg-negative/anti-HBcAb-positive patients undergoing check details cancer therapy, especially in males presenting with haematological cancer,

a low anti-HBsAb titre and more than one chemotherapeutic agent. HBV DNA testing is mandatory to improve diagnosis and management of HBV-R in these patients. The role of specific therapies such as rituximab or HSCT as well as of HBV aa variability deserves further studies.”
“Background: Adequate fibrinogen concentration is a crucial component of sufficient perioperative/posttraumatic hemostasis. In major blood loss, Avapritinib large volumes of fluids are being administered, which have been shown to interfere with valid determination of fibrinogen concentration. This may lead to wrong treatment decisions. We studied the variables that cause the discrepancies between measured and true fibrinogen concentrations in

samples diluted with volume replacement fluids. Methods: Citrated plasma samples of healthy volunteers were diluted by 30% and 50% with phosphate buffered saline (PBS), hydroxyethyl starch (HES) 10% (200/0.5), or gelatine (GEL). Fibrinogen concentrations of diluted samples were derived from the prothrombin time (PT) and the Clauss method (CLS) was applied. With the latter, several modifications and combinations of detection principles and thrombin reagents were investigated. Values were compared with “”true,”" that is, calculated values based on the results of undiluted 8-Bromo-cAMP samples for each method. Results: Photo-optical methods resulted in significant overestimation of the fibrinogen concentration in blood diluted with HES, depending on the thrombin reagent used. This was particularly true for modifications of the CLS aimed at measuring low fibrinogen concentrations. Use of another thrombin reagent gave satisfactory results for this modification. The validity of mechanical end point determination methods was considered sufficient and was not influenced by the use of different thrombin reagents. Conclusions: Fibrinogen determination methods used in situations of major blood loss need to be validated with samples containing significant amounts of volume replacement fluids, particularly colloids.

Comments are closed.